Applications: |
ELISA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.19ng/mL |
Detection Limit: |
0.31~20ng/mL |
Short Description: |
This LDLR Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human cell culture supernatant, serum and plasma (EDTA, citrate, heparin). |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Colormetric |
Gene Symbol: |
LDLR |
Gene ID: |
3949 |
Uniprot ID: |
LDLR_HUMAN |
Specificity: |
This kit recognizes Human LDLR in samples. No significant cross-reactivity or interference between Human LDLR and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | Binds LDL, the major cholesterol-carrying lipoprotein of plasma, and transports it into cells by endocytosis. In order to be internalized, the receptor-ligand complexes must first cluster into clathrin-coated pits. (Microbial infection) Acts as a receptor for hepatitis C virus in hepatocytes, but not through a direct interaction with viral proteins. (Microbial infection) Acts as a receptor for Vesicular stomatitis virus. (Microbial infection) In case of HIV-1 infection, may function as a receptor for extracellular Tat in neurons, mediating its internalization in uninfected cells. |
Protein Name | Low-Density Lipoprotein ReceptorLdl Receptor |
Database Links | Reactome: R-HSA-8856825Reactome: R-HSA-8856828Reactome: R-HSA-8964026Reactome: R-HSA-8964038Reactome: R-HSA-975634 |
Cellular Localisation | Cell MembraneSingle-Pass Type I Membrane ProteinMembraneClathrin-Coated PitGolgi ApparatusEarly EndosomeLate EndosomeLysosomeRapidly Endocytosed Upon Ligand Binding |
Alternative ELISA Names | Low-Density Lipoprotein Receptor ELISA kitLdl Receptor ELISA kitLDLR ELISA kit |
Specificity | This kit recognizes Human LDLR in samples. No significant cross-reactivity or interference between Human LDLR and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 90-108 | 98 |
EDTA plasma (n=8) | 87-103 | 94 |
Cell culture media (n=8) | 94-105 | 100 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 1.01 | 1.70 | 7.95 | 0.95 | 1.81 | 8.59 |
Standard deviation | 0.05 | 0.09 | 0.38 | 0.05 | 0.08 | 0.37 |
CV (%) | 4.95 | 5.29 | 4.78 | 5.26 | 4.42 | 4.31 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance