• Human IL32 (Interleukin-32) CLIA Kit (STJC0000156)

Human IL32 (Interleukin-32) CLIA Kit (STJC0000156)

SKU:
STJC0000156

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This human IL32 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: IL32
Gene ID: 9235
Uniprot ID: IL32_HUMAN
Specificity: This kit recognizes Human IL-32 in samples. No significant cross-reactivity or interference between Human IL-32 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Selectively expressed in lymphocytes. Expression is more prominent in immune cells than in non-immune cells.
Function Cytokine that may play a role in innate and adaptive immune responses. It induces various cytokines such as TNFA/TNF-alpha and IL8. It activates typical cytokine signal pathways of NF-kappa-B and p38 MAPK.
Protein Name Interleukin-32
Il-32
Natural Killer Cells Protein 4
Tumor Necrosis Factor Alpha-Inducing Factor
Database Links Reactome: R-HSA-449836
Reactome: R-HSA-9013423
Cellular Localisation Secreted
Alternative CLIA Names Interleukin-32 CLIA kit
Il-32 CLIA kit
Natural Killer Cells Protein 4 CLIA kit
Tumor Necrosis Factor Alpha-Inducing Factor CLIA kit
IL32 CLIA kit
NK4 CLIA kit
TAIF CLIA kit
Specificity This kit recognizes Human IL-32 in samples. No significant cross-reactivity or interference between Human IL-32 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 99-114 104
EDTA plasma(n=8) 86-97 92
Cell culture media(n=8) 83-96 90

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 24.96 50.03 241.26 27.20 49.40 219.06
Standard deviation 2.15 4.68 15.63 2.65 4.46 22.56
CV (%) 8.61 9.35 6.48 9.74 9.03 10.30
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance