• Human IL19 (Interleukin-19) CLIA Kit (STJC0000165)

Human IL19 (Interleukin-19) CLIA Kit (STJC0000165)

SKU:
STJC0000165

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This human IL19 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: IL19
Gene ID: 29949
Uniprot ID: IL19_HUMAN
Specificity: This kit recognizes Human IL-19 in samples. No significant cross-reactivity or interference between Human IL-19 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Cytokine that functions as an anti-inflammatory and proangiogenic factor. Polarizes adaptive immunity to an anti-inflammatory phenotype through induction of T-helper 2 responses by both down-regulation of IFN-gamma and up-regulation of IL4 and IL13. Produced by osteocytes, stimulates granulopoiesis and neutrophil formation. Exerts its biological effect through a receptor complex consisting of a heterodimer of IL20RA and IL20RB. In turn, activates the Janus kinase (JAK) and signal transducer and activator of transcription (STAT) pathway, and importantly, STAT3.
Protein Name Interleukin-19
Il-19
Melanoma Differentiation-Associated Protein-Like Protein
Ng.1
Database Links Reactome: R-HSA-8854691
Cellular Localisation Secreted
Alternative CLIA Names Interleukin-19 CLIA kit
Il-19 CLIA kit
Melanoma Differentiation-Associated Protein-Like Protein CLIA kit
Ng.1 CLIA kit
IL19 CLIA kit
ZMDA1 CLIA kit
Specificity This kit recognizes Human IL-19 in samples. No significant cross-reactivity or interference between Human IL-19 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 99-114 107
EDTA plasma(n=8) 100-113 107
Cell culture media(n=8) 100-114 105

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 38.97 110.52 352.86 38.53 119.24 379.87
Standard deviation 3.57 11.59 24.49 4.83 12.46 25.11
CV (%) 9.16 10.49 6.94 12.54 10.45 6.61
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance