Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
7.5pg/mL |
Detection Limit: |
12.5~800pg/mL |
Short Description: |
This human IL19 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
IL19 |
Gene ID: |
29949 |
Uniprot ID: |
IL19_HUMAN |
Specificity: |
This kit recognizes Human IL-19 in samples. No significant cross-reactivity or interference between Human IL-19 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | Cytokine that functions as an anti-inflammatory and proangiogenic factor. Polarizes adaptive immunity to an anti-inflammatory phenotype through induction of T-helper 2 responses by both down-regulation of IFN-gamma and up-regulation of IL4 and IL13. Produced by osteocytes, stimulates granulopoiesis and neutrophil formation. Exerts its biological effect through a receptor complex consisting of a heterodimer of IL20RA and IL20RB. In turn, activates the Janus kinase (JAK) and signal transducer and activator of transcription (STAT) pathway, and importantly, STAT3. |
Protein Name | Interleukin-19Il-19Melanoma Differentiation-Associated Protein-Like ProteinNg.1 |
Database Links | Reactome: R-HSA-8854691 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Interleukin-19 CLIA kitIl-19 CLIA kitMelanoma Differentiation-Associated Protein-Like Protein CLIA kitNg.1 CLIA kitIL19 CLIA kitZMDA1 CLIA kit |
Specificity | This kit recognizes Human IL-19 in samples. No significant cross-reactivity or interference between Human IL-19 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 99-114 | 107 |
EDTA plasma(n=8) | 100-113 | 107 |
Cell culture media(n=8) | 100-114 | 105 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 38.97 | 110.52 | 352.86 | 38.53 | 119.24 | 379.87 |
Standard deviation | 3.57 | 11.59 | 24.49 | 4.83 | 12.46 | 25.11 |
CV (%) | 9.16 | 10.49 | 6.94 | 12.54 | 10.45 | 6.61 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance