• Human ICAM4 (Intercellular adhesion molecule 4) CLIA Kit (STJC0000251)

Human ICAM4 (Intercellular adhesion molecule 4) CLIA Kit (STJC0000251)

SKU:
STJC0000251

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.38ng/mL
Detection Limit: 0.63~40ng/mL
Short Description: This human ICAM4 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: ICAM4
Gene ID: 3386
Uniprot ID: ICAM4_HUMAN
Specificity: This kit recognizes Human ICAM4 in samples. No significant cross-reactivity or interference between Human ICAM4 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Erythrocytes.
Post Translational Modifications N- and O-glycosylated.
Function ICAM proteins are ligands for the leukocyte adhesion protein LFA-1 (integrin alpha-L/beta-2). ICAM4 is also a ligand for alpha-4/beta-1 and alpha-V integrins.
Protein Name Intercellular Adhesion Molecule 4
Icam-4
Landsteiner-Wiener Blood Group Glycoprotein
Lw Blood Group Protein
Cd Antigen Cd242
Database Links Reactome: R-HSA-198933
Reactome: R-HSA-216083
Cellular Localisation Isoform Long: Cell Membrane
Single-Pass Type I Membrane Protein
Isoform Short: Secreted
Cell Membrane
Alternative CLIA Names Intercellular Adhesion Molecule 4 CLIA kit
Icam-4 CLIA kit
Landsteiner-Wiener Blood Group Glycoprotein CLIA kit
Lw Blood Group Protein CLIA kit
Cd Antigen Cd242 CLIA kit
ICAM4 CLIA kit
LW CLIA kit
Specificity This kit recognizes Human ICAM4 in samples. No significant cross-reactivity or interference between Human ICAM4 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 94-111 101
EDTA plasma(n=8) 86-101 93
Cell culture media(n=8) 92-104 99

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 2.04 3.79 18.22 2.17 3.71 17.70
Standard deviation 0.26 0.28 1.86 0.18 0.41 1.79
CV (%) 12.75 7.39 10.21 8.29 11.05 10.11
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance