• Human GPRC5A (Retinoic acid-induced protein 3) CLIA Kit (STJC0000515)

Human GPRC5A (Retinoic acid-induced protein 3) CLIA Kit (STJC0000515)

SKU:
STJC0000515

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human GPRC5A kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: GPRC5A
Gene ID: 9052
Uniprot ID: RAI3_HUMAN
Specificity: This kit recognizes Human GPRC5A in samples. No significant cross-reactivity or interference between Human GPRC5A and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed at high level in fetal and adult lung tissues but repressed in most human lung cancers. Constitutively expressed in fetal kidney and adult placenta, kidney, prostate, testis, ovary, small intestine, colon, stomach, and spinal cord at low to moderate levels. Not detectable in fetal heart, brain, and liver and adult heart, brain, liver, skeletal muscle, pancreas, spleen, thymus, and peripheral leukocytes. expressed at low but detectable level in pancreas and heart.
Post Translational Modifications Phosphorylated in two conserved double-tyrosine motifs, Tyr-317/Tyr-320 and Tyr-347/Tyr-350, by EGFR.leading to inactivation of the tumor suppressive function of GPRC5A in lung cancer cells. Tyr-317 and Tyr-320 are the preferred residues responsible for EGFR-mediated GPRC5A phosphorylation.
Function Orphan receptor. Could be involved in modulating differentiation and maintaining homeostasis of epithelial cells. This retinoic acid-inducible GPCR provide evidence for a possible interaction between retinoid and G-protein signaling pathways. Functions as a negative modulator of EGFR signaling. May act as a lung tumor suppressor.
Protein Name Retinoic Acid-Induced Protein 3
G-Protein Coupled Receptor Family C Group 5 Member A
Phorbol Ester Induced Gene 1
Peig-1
Retinoic Acid-Induced Gene 1 Protein
Raig-1
Cellular Localisation Cell Membrane
Multi-Pass Membrane Protein
Cytoplasmic Vesicle Membrane
Localized In Perinuclear Vesicles
Probably Golgi-Associated Vesicles
Alternative CLIA Names Retinoic Acid-Induced Protein 3 CLIA kit
G-Protein Coupled Receptor Family C Group 5 Member A CLIA kit
Phorbol Ester Induced Gene 1 CLIA kit
Peig-1 CLIA kit
Retinoic Acid-Induced Gene 1 Protein CLIA kit
Raig-1 CLIA kit
GPRC5A CLIA kit
GPCR5A CLIA kit
RAI3 CLIA kit
RAIG1 CLIA kit
Specificity This kit recognizes Human GPRC5A in samples. No significant cross-reactivity or interference between Human GPRC5A and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-108 101
EDTA plasma(n=8) 84-96 90
Cell culture media(n=8) 93-108 99

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 188.24 419.40 1399.72 188.31 452.08 1309.06
Standard deviation 21.33 31.71 93.22 15.35 48.55 125.80
CV (%) 11.33 7.56 6.66 8.15 10.74 9.61
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance