Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human GJB1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
GJB1 |
Gene ID: |
2705 |
Uniprot ID: |
CXB1_HUMAN |
Specificity: |
This kit recognizes Human GJ Beta 1 in samples. No significant cross-reactivity or interference between Human GJ Beta 1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | One gap junction consists of a cluster of closely packed pairs of transmembrane channels, the connexons, through which materials of low MW diffuse from one cell to a neighboring cell. |
Protein Name | Gap Junction Beta-1 ProteinConnexin-32Cx32Gap Junction 28 Kda Liver Protein |
Database Links | Reactome: R-HSA-190704Reactome: R-HSA-190827Reactome: R-HSA-190861 |
Cellular Localisation | Cell MembraneMulti-Pass Membrane ProteinCell JunctionGap Junction |
Alternative CLIA Names | Gap Junction Beta-1 Protein CLIA kitConnexin-32 CLIA kitCx32 CLIA kitGap Junction 28 Kda Liver Protein CLIA kitGJB1 CLIA kitCX32 CLIA kit |
Specificity | This kit recognizes Human GJβ1 in samples. No significant cross-reactivity or interference between Human GJβ1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 93-108 | 99 |
EDTA plasma(n=8) | 91-101 | 96 |
Cell culture media(n=8) | 88-102 | 94 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 196.14 | 533.30 | 1372.83 | 192.24 | 570.82 | 1434.80 |
Standard deviation | 20.67 | 45.70 | 100.90 | 15.96 | 66.61 | 118.37 |
CV (%) | 10.54 | 8.57 | 7.35 | 8.30 | 11.67 | 8.25 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance