• Human GJB1 (Gap junction beta-1 protein) CLIA Kit (STJC0000665)

Human GJB1 (Gap junction beta-1 protein) CLIA Kit (STJC0000665)

SKU:
STJC0000665

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human GJB1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: GJB1
Gene ID: 2705
Uniprot ID: CXB1_HUMAN
Specificity: This kit recognizes Human GJ Beta 1 in samples. No significant cross-reactivity or interference between Human GJ Beta 1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function One gap junction consists of a cluster of closely packed pairs of transmembrane channels, the connexons, through which materials of low MW diffuse from one cell to a neighboring cell.
Protein Name Gap Junction Beta-1 Protein
Connexin-32
Cx32
Gap Junction 28 Kda Liver Protein
Database Links Reactome: R-HSA-190704
Reactome: R-HSA-190827
Reactome: R-HSA-190861
Cellular Localisation Cell Membrane
Multi-Pass Membrane Protein
Cell Junction
Gap Junction
Alternative CLIA Names Gap Junction Beta-1 Protein CLIA kit
Connexin-32 CLIA kit
Cx32 CLIA kit
Gap Junction 28 Kda Liver Protein CLIA kit
GJB1 CLIA kit
CX32 CLIA kit
Specificity This kit recognizes Human GJβ1 in samples. No significant cross-reactivity or interference between Human GJβ1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-108 99
EDTA plasma(n=8) 91-101 96
Cell culture media(n=8) 88-102 94

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 196.14 533.30 1372.83 192.24 570.82 1434.80
Standard deviation 20.67 45.70 100.90 15.96 66.61 118.37
CV (%) 10.54 8.57 7.35 8.30 11.67 8.25
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance