• Human FGL2 (Fibroleukin) CLIA Kit (STJC0000892)

Human FGL2 (Fibroleukin) CLIA Kit (STJC0000892)

SKU:
STJC0000892

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human FGL2 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: FGL2
Gene ID: 10875
Uniprot ID: FGL2_HUMAN
Specificity: This kit recognizes Human FGL2 in samples. No significant cross-reactivity or interference between Human FGL2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Constitutively expressed in cytotoxic T-cells.
Function May play a role in physiologic lymphocyte functions at mucosal sites.
Protein Name Fibroleukin
Fibrinogen-Like Protein 2
Pt49
Database Links Reactome: R-HSA-6798695
Cellular Localisation Secreted
Alternative CLIA Names Fibroleukin CLIA kit
Fibrinogen-Like Protein 2 CLIA kit
Pt49 CLIA kit
FGL2 CLIA kit
Specificity This kit recognizes Human FGL2 in samples. No significant cross-reactivity or interference between Human FGL2 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-106 99
EDTA plasma(n=8) 100-116 106
Cell culture media(n=8) 87-98 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 55.07 138.96 388.61 51.49 129.67 375.06
Standard deviation 5.82 12.09 29.65 4.65 14.61 40.54
CV (%) 10.57 8.70 7.63 9.03 11.27 10.81
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance