• Human EPCAM (Epithelial cell adhesion molecule) CLIA Kit (STJC0000819)

Human EPCAM (Epithelial cell adhesion molecule) CLIA Kit (STJC0000819)

SKU:
STJC0000819

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19IU/mL
Detection Limit: 0.31~20IU/mL
Short Description: This human EPCAM kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: EPCAM
Gene ID: 4072
Uniprot ID: EPCAM_HUMAN
Specificity: This kit recognizes Human Ep-CAM/CD326 in samples. No significant cross-reactivity or interference between Human Ep-CAM/CD326 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Highly and selectively expressed by undifferentiated rather than differentiated embryonic stem cells (ESC). Levels rapidly diminish as soon as ESC's differentiate (at protein levels). Expressed in almost all epithelial cell membranes but not on mesodermal or neural cell membranes. Found on the surface of adenocarcinoma.
Post Translational Modifications Hyperglycosylated in carcinoma tissue as compared with autologous normal epithelia. Glycosylation at Asn-198 is crucial for protein stability.
Function May act as a physical homophilic interaction molecule between intestinal epithelial cells (IECs) and intraepithelial lymphocytes (IELs) at the mucosal epithelium for providing immunological barrier as a first line of defense against mucosal infection. Plays a role in embryonic stem cells proliferation and differentiation. Up-regulates the expression of FABP5, MYC and cyclins A and E.
Protein Name Epithelial Cell Adhesion Molecule
Ep-Cam
Adenocarcinoma-Associated Antigen
Cell Surface Glycoprotein Trop-1
Epithelial Cell Surface Antigen
Epithelial Glycoprotein
Egp
Epithelial Glycoprotein 314
Egp314
Hegp314
Ks 1/4 Antigen
Ksa
Major Gastrointestinal Tumor-Associated Protein Ga733-2
Tumor-Associated Calcium Signal Transducer 1
Cd Antigen Cd326
Database Links Reactome: R-HSA-202733
Cellular Localisation Lateral Cell Membrane
Single-Pass Type I Membrane Protein
Cell Junction
Tight Junction
Colocalizes With Cldn7 At The Lateral Cell Membrane And Tight Junction
Alternative CLIA Names Epithelial Cell Adhesion Molecule CLIA kit
Ep-Cam CLIA kit
Adenocarcinoma-Associated Antigen CLIA kit
Cell Surface Glycoprotein Trop-1 CLIA kit
Epithelial Cell Surface Antigen CLIA kit
Epithelial Glycoprotein CLIA kit
Egp CLIA kit
Epithelial Glycoprotein 314 CLIA kit
Egp314 CLIA kit
Hegp314 CLIA kit
Ks 1/4 Antigen CLIA kit
Ksa CLIA kit
Major Gastrointestinal Tumor-Associated Protein Ga733-2 CLIA kit
Tumor-Associated Calcium Signal Transducer 1 CLIA kit
Cd Antigen Cd326 CLIA kit
EPCAM CLIA kit
GA733-2 CLIA kit
M1S2 CLIA kit
M4S1 CLIA kit
MIC18 CLIA kit
TACSTD1 CLIA kit
TROP1 CLIA kit
Specificity This kit recognizes Human Ep-CAM/CD326 in samples. No significant cross-reactivity or interference between Human Ep-CAM/CD326 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-107 100
EDTA plasma(n=8) 87-97 92
Cell culture media(n=8) 96-114 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (IU/mL) 0.91 1.91 7.30 0.86 1.75 7.13
Standard deviation 0.09 0.22 0.75 0.07 0.14 0.49
CV (%) 9.89 11.52 10.27 8.14 8.00 6.87
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance