Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human DRD1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DRD1
Gene ID: 1812
Uniprot ID: DRD1_HUMAN
Specificity: This kit recognizes Human D1R/DRD1 in samples. No significant cross-reactivity or interference between Human D1R/DRD1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Detected in caudate, nucleus accumbens and in the olfactory tubercle.
Function Dopamine receptor whose activity is mediated by G proteins which activate adenylyl cyclase.
Protein Name D(1a Dopamine Receptor
Dopamine D1 Receptor
Database Links Reactome: R-HSA-390651
Reactome: R-HSA-418555
Cellular Localisation Cell Membrane
Multi-Pass Membrane Protein
Endoplasmic Reticulum Membrane
Cell Projection
Dendrite
Dendritic Spine
Transport From The Endoplasmic Reticulum To The Cell Surface Is Regulated By Interaction With Dnajc14
Alternative CLIA Names D(1a Dopamine Receptor CLIA kit
Dopamine D1 Receptor CLIA kit
DRD1 CLIA kit
Specificity This kit recognizes Human D1R/DRD1 in samples. No significant cross-reactivity or interference between Human D1R/DRD1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 89-102 94
EDTA plasma(n=8) 94-107 102
Cell culture media(n=8) 93-110 100

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 199.76 485.03 1849.79 194.12 468.65 1670.02
Standard deviation 17.16 56.41 183.13 15.94 41.76 169.84
CV (%) 8.59 11.63 9.90 8.21 8.91 10.17
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance