• Human DLK1 (Protein delta homolog 1) CLIA Kit (STJC0000179)

Human DLK1 (Protein delta homolog 1) CLIA Kit (STJC0000179)

SKU:
STJC0000179

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human DLK1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DLK1
Gene ID: 8788
Uniprot ID: DLK1_HUMAN
Specificity: This kit recognizes Human DLK-1 in samples. No significant cross-reactivity or interference between Human DLK-1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Found within the stromal cells in close contact to the vascular structure of placental villi, yolk sac, fetal liver, adrenal cortex and pancreas and in the beta cells of the islets of Langerhans in the adult pancreas. Found also in some forms of neuroendocrine lung tumor tissue.
Post Translational Modifications N- and O-glycosylated. O-glycosylated with core 1 or possibly core 8 glycans.
Function May have a role in neuroendocrine differentiation.
Protein Name Protein Delta Homolog 1
Dlk-1
Pg2 Cleaved Into - Fetal Antigen 1
Fa1
Database Links Reactome: R-HSA-2122948
Cellular Localisation Membrane
Single-Pass Type I Membrane Protein
Cytoplasm
Alternative CLIA Names Protein Delta Homolog 1 CLIA kit
Dlk-1 CLIA kit
Pg2 Cleaved Into - Fetal Antigen 1 CLIA kit
Fa1 CLIA kit
DLK1 CLIA kit
DLK CLIA kit
Specificity This kit recognizes Human DLK-1 in samples. No significant cross-reactivity or interference between Human DLK-1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 84-98 90
EDTA plasma(n=8) 95-109 102
Cell culture media(n=8) 89-101 95

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 95.75 200.79 694.27 96.69 204.04 671.36
Standard deviation 9.52 22.95 65.89 8.67 22.79 53.71
CV (%) 9.94 11.43 9.49 8.97 11.17 8.00
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance