• Human DEFB1 (Beta-defensin 1) CLIA Kit (STJC0000484)

Human DEFB1 (Beta-defensin 1) CLIA Kit (STJC0000484)

SKU:
STJC0000484

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human DEFB1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DEFB1
Gene ID: 1672
Uniprot ID: DEFB1_HUMAN
Specificity: This kit recognizes Human DEFB1 in samples. No significant cross-reactivity or interference between Human DEFB1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Blood plasma. Sperm. Highly expressed in the lower head and midpiece of sperm. Significantly reduced levels found in the sperms of asthenozoospermia and leukocytospermia patients (at protein level).
Function Has bactericidal activity. May act as a ligand for C-C chemokine receptor CCR6. Positively regulates the sperm motility and bactericidal activity in a CCR6-dependent manner. Binds to CCR6 and triggers Ca2+ mobilization in the sperm which is important for its motility.
Protein Name Beta-Defensin 1
Bd-1
Hbd-1
Defensin - Beta 1
Database Links Reactome: R-HSA-1461957
Reactome: R-HSA-1461973
Cellular Localisation Secreted
Membrane
Associates With Tumor Cell Membrane-Derived Microvesicles
Alternative CLIA Names Beta-Defensin 1 CLIA kit
Bd-1 CLIA kit
Hbd-1 CLIA kit
Defensin - Beta 1 CLIA kit
DEFB1 CLIA kit
BD1 CLIA kit
HBD1 CLIA kit
Specificity This kit recognizes Human DEFB1 in samples. No significant cross-reactivity or interference between Human DEFB1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 94-107 99
EDTA plasma(n=8) 91-105 98
Cell culture media(n=8) 87-101 94

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 50.48 150.66 477.74 46.71 140.15 469.68
Standard deviation 5.14 13.73 42.09 5.06 10.75 43.12
CV (%) 10.18 9.11 8.81 10.83 7.67 9.18
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance