• Human CYB5A (Cytochrome b5) CLIA Kit (STJC0000731)

Human CYB5A (Cytochrome b5) CLIA Kit (STJC0000731)

SKU:
STJC0000731

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human CYB5A kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CYB5A
Gene ID: 1528
Uniprot ID: CYB5_HUMAN
Specificity: This kit recognizes Human CYB5A in samples. No significant cross-reactivity or interference between Human CYB5A and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Cytochrome b5 is a membrane-bound hemoprotein functioning as an electron carrier for several membrane-bound oxygenases.
Protein Name Cytochrome B5
Microsomal Cytochrome B5 Type A
Mcb5
Database Links Reactome: R-HSA-196836
Reactome: R-HSA-9609523 P00167-1
Cellular Localisation Isoform 1: Endoplasmic Reticulum Membrane
Single-Pass Membrane Protein
Cytoplasmic Side
Microsome Membrane
Isoform 2: Cytoplasm
Alternative CLIA Names Cytochrome B5 CLIA kit
Microsomal Cytochrome B5 Type A CLIA kit
Mcb5 CLIA kit
CYB5A CLIA kit
CYB5 CLIA kit
Specificity This kit recognizes Human CYB5A in samples. No significant cross-reactivity or interference between Human CYB5A and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 98-110 104
EDTA plasma(n=8) 88-102 94
Cell culture media(n=8) 93-105 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 99.16 179.08 668.16 104.14 177.64 654.12
Standard deviation 12.02 20.88 54.46 13.11 17.05 55.08
CV (%) 12.12 11.66 8.15 12.59 9.60 8.42
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance