• Human CSF3 (Granulocyte colony-stimulating factor) CLIA Kit (STJC0000073)

Human CSF3 (Granulocyte colony-stimulating factor) CLIA Kit (STJC0000073)

SKU:
STJC0000073

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This human CSF3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CSF3
Gene ID: 1440
Uniprot ID: CSF3_HUMAN
Specificity: This kit recognizes Human G-CSF in samples. No significant cross-reactivity or interference between Human G-CSF and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications O-glycan consists of Gal-GalNAc disaccharide which can be modified with up to two sialic acid residues (done in recombinantly expressed G-CSF from CHO cells).
Function Granulocyte/macrophage colony-stimulating factors are cytokines that act in hematopoiesis by controlling the production, differentiation, and function of 2 related white cell populations of the blood, the granulocytes and the monocytes-macrophages. This CSF induces granulocytes.
Protein Name Granulocyte Colony-Stimulating Factor
G-Csf
Pluripoietin
Filgrastim
Lenograstim
Database Links Reactome: R-HSA-449836
Reactome: R-HSA-6783783
Reactome: R-HSA-9674555
Reactome: R-HSA-9705462
Cellular Localisation Secreted
Alternative CLIA Names Granulocyte Colony-Stimulating Factor CLIA kit
G-Csf CLIA kit
Pluripoietin CLIA kit
Filgrastim CLIA kit
Lenograstim CLIA kit
CSF3 CLIA kit
C17orf33 CLIA kit
GCSF CLIA kit
Specificity This kit recognizes Human G-CSF in samples. No significant cross-reactivity or interference between Human G-CSF and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 95-109 101
EDTA plasma(n=8) 93-108 98
Cell culture media(n=8) 83-97 90

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 37.35 101.99 383.49 37.71 104.98 353.05
Standard deviation 4.32 10.75 33.98 3.16 10.60 30.61
CV (%) 11.57 10.54 8.86 8.38 10.10 8.67
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance