Applications: |
ELISA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.47ng/mL |
Detection Limit: |
0.78-50ng/mL |
Short Description: |
This CEACAM5 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human cell culture supernatant, serum and plasma (EDTA, citrate, heparin). |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 6 months. Following first use any unused wells and reagents should be stored according to the components table in the manual. |
Assay Time: |
1.5h |
Detection: |
Colormetric |
Gene Symbol: |
CEACAM5 |
Gene ID: |
1048 |
Uniprot ID: |
CEAM5_HUMAN |
Specificity: |
This kit recognizes Human CEA in samples. No significant cross-reactivity or interference between Human CEA and analogues was observed. |
Sample Type: |
Serum and plasma |
Post Translational Modifications | Complex immunoreactive glycoprotein with a MW of 180 kDa comprising 60% carbohydrate. |
Function | Cell surface glycoprotein that plays a role in cell adhesion, intracellular signaling and tumor progression. Mediates homophilic and heterophilic cell adhesion with other carcinoembryonic antigen-related cell adhesion molecules, such as CEACAM6. Plays a role as an oncogene by promoting tumor progression.induces resistance to anoikis of colorectal carcinoma cells. (Microbial infection) Receptor for E.coli Dr adhesins. Binding of E.coli Dr adhesins leads to dissociation of the homodimer. |
Protein Name | Carcinoembryonic Antigen-Related Cell Adhesion Molecule 5Carcinoembryonic AntigenCeaMeconium Antigen 100Cd Antigen Cd66e |
Database Links | Reactome: R-HSA-163125Reactome: R-HSA-202733 |
Cellular Localisation | Cell MembraneLipid-AnchorGpi-AnchorApical Cell MembraneCell SurfaceLocalized To The Apical Glycocalyx Surface |
Alternative ELISA Names | Carcinoembryonic Antigen-Related Cell Adhesion Molecule 5 ELISA kitCarcinoembryonic Antigen ELISA kitCea ELISA kitMeconium Antigen 100 ELISA kitCd Antigen Cd66e ELISA kitCEACAM5 ELISA kitCEA ELISA kit |
Specificity | This kit recognizes CEA in samples. No significant cross-reactivity or interference between CEA and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T | 2-8℃, 1 months |
Reference Standard | 96T: 2 vials 48T/24T: 1 vial 96T*5: 10 vials | 2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab (100×) | 96T: 1 vial, 60 μL 48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL | 2-8℃ (Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL96T*5: 5 vials, 20 mL | 2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL96T*5: 5 vials, 14 mL | |
Concentrated Wash Buffer (25×) | 96T/48T/24T: 1 vial, 30 mL96T*5: 5 vials, 30 mL | |
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL96T*5: 5 vials, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL96T*5: 5 vials, 10 mL | 2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces96T*5: 25 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 93-107 | 100 |
EDTA plasma(n=8) | 87-98 | 92 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 2.44 | 7.17 | 18.89 | 2.29 | 6.53 | 19.86 |
Standard deviation | 0.13 | 0.40 | 0.60 | 0.13 | 0.26 | 0.66 |
CV (%) | 5.16 | 5.51 | 3.16 | 5.79 | 4.01 | 3.32 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance