• Human CCL27 (C-C motif chemokine 27) CLIA Kit (STJC0000031)

Human CCL27 (C-C motif chemokine 27) CLIA Kit (STJC0000031)

SKU:
STJC0000031

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This human CCL27 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CCL27
Gene ID: 10850
Uniprot ID: CCL27_HUMAN
Specificity: This kit recognizes Human CTACK in samples. No significant cross-reactivity or interference between Human CTACK and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Testis, thymus, placenta, ovary and skin.
Function Chemotactic factor that attracts skin-associated memory T-lymphocytes. May play a role in mediating homing of lymphocytes to cutaneous sites. Binds to CCR10.
Protein Name C-C Motif Chemokine 27
Cc Chemokine Ilc
Cutaneous T-Cell-Attracting Chemokine
Ctack
Eskine
Il-11 R-Alpha-Locus Chemokine
Skinkine
Small-Inducible Cytokine A27
Database Links Reactome: R-HSA-380108
Reactome: R-HSA-418594
Cellular Localisation Secreted
Alternative CLIA Names C-C Motif Chemokine 27 CLIA kit
Cc Chemokine Ilc CLIA kit
Cutaneous T-Cell-Attracting Chemokine CLIA kit
Ctack CLIA kit
Eskine CLIA kit
Il-11 R-Alpha-Locus Chemokine CLIA kit
Skinkine CLIA kit
Small-Inducible Cytokine A27 CLIA kit
CCL27 CLIA kit
ILC CLIA kit
SCYA27 CLIA kit
Specificity This kit recognizes Human CTACK in samples. No significant cross-reactivity or interference between Human CTACK and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 100-113 107
EDTA plasma(n=8) 94-107 101
Cell culture media(n=8) 99-114 107

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 36.42 69.49 380.71 39.32 72.52 365.96
Standard deviation 3.35 5.69 23.76 3.22 6.63 35.13
CV (%) 9.20 8.19 6.24 8.19 9.14 9.60
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance