• Human CCL26 (C-C motif chemokine 26) CLIA Kit (STJC0000030)

Human CCL26 (C-C motif chemokine 26) CLIA Kit (STJC0000030)

SKU:
STJC0000030

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human CCL26 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CCL26
Gene ID: 10344
Uniprot ID: CCL26_HUMAN
Specificity: This kit recognizes Human MIP4 Alpha in samples. No significant cross-reactivity or interference between Human MIP4 Alpha and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Ubiquitously expressed at low levels in various tissues including heart and ovary.
Function Chemoattractant for eosinophils and basophils. Acts as a ligand for C-C chemokine receptor CCR3 which triggers Ca(2+) mobilization in eosinophils. Also acts as a ligand for CX3C chemokine receptor CX3CR1, inducing cell chemotaxis.
Protein Name C-C Motif Chemokine 26
Cc Chemokine Imac
Eotaxin-3
Macrophage Inflammatory Protein 4-Alpha
Mip-4-Alpha
Small-Inducible Cytokine A26
Thymic Stroma Chemokine-1
Tsc-1
Cellular Localisation Secreted
Alternative CLIA Names C-C Motif Chemokine 26 CLIA kit
Cc Chemokine Imac CLIA kit
Eotaxin-3 CLIA kit
Macrophage Inflammatory Protein 4-Alpha CLIA kit
Mip-4-Alpha CLIA kit
Small-Inducible Cytokine A26 CLIA kit
Thymic Stroma Chemokine-1 CLIA kit
Tsc-1 CLIA kit
CCL26 CLIA kit
SCYA26 CLIA kit
UNQ216 CLIA kit
PRO242 CLIA kit
Specificity This kit recognizes Human MIP4α in samples. No significant cross-reactivity or interference between Human MIP4α and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 96-108 103
EDTA plasma(n=8) 99-117 106
Cell culture media(n=8) 91-102 97

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 47.88 91.75 382.74 43.80 96.24 368.42
Standard deviation 4.95 7.32 30.58 5.46 8.88 42.26
CV (%) 10.34 7.98 7.99 12.47 9.23 11.47
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance