• Human CA1 (Carbonic anhydrase 1) CLIA Kit (STJC0000347)

Human CA1 (Carbonic anhydrase 1) CLIA Kit (STJC0000347)

SKU:
STJC0000347

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human CA1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CA1
Gene ID: 759
Uniprot ID: CAH1_HUMAN
Specificity: This kit recognizes Human CA1 in samples. No significant cross-reactivity or interference between Human CA1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Catalyzes the reversible hydration of carbon dioxide. Can hydrate cyanamide to urea.
Protein Name Carbonic Anhydrase 1
Carbonate Dehydratase I
Carbonic Anhydrase B
Cab
Carbonic Anhydrase I
Ca-I
Cyanamide Hydratase Ca1
Database Links Reactome: R-HSA-1237044
Reactome: R-HSA-1247673
Reactome: R-HSA-1475029
Reactome: R-HSA-8950505
Cellular Localisation Cytoplasm
Alternative CLIA Names Carbonic Anhydrase 1 CLIA kit
Carbonate Dehydratase I CLIA kit
Carbonic Anhydrase B CLIA kit
Cab CLIA kit
Carbonic Anhydrase I CLIA kit
Ca-I CLIA kit
Cyanamide Hydratase Ca1 CLIA kit
CA1 CLIA kit
Specificity This kit recognizes Human CA1 in samples. No significant cross-reactivity or interference between Human CA1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-101 92
EDTA plasma(n=8) 92-106 98
Cell culture media(n=8) 97-113 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 1.02 1.75 6.92 0.95 1.61 6.71
Standard deviation 0.12 0.13 0.77 0.12 0.14 0.65
CV (%) 11.76 7.43 11.13 12.63 8.70 9.69
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance