Applications: |
ELISA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
46.88pg/mL |
Detection Limit: |
78.13~5000pg/mL |
Short Description: |
This C5 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human cell culture supernatant, serum and plasma (EDTA, citrate, heparin). |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Colormetric |
Gene Symbol: |
C5 |
Gene ID: |
727 |
Uniprot ID: |
CO5_HUMAN |
Specificity: |
This kit recognizes Human C5 in samples. No significant cross-reactivity or interference between Human C5 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Protein Name | Complement C5C3 And Pzp-Like Alpha-2-Macroglobulin Domain-Containing Protein 4 Cleaved Into - Complement C5 Beta Chain - Complement C5 Alpha Chain - C5a Anaphylatoxin - Complement C5 Alpha' Chain |
Database Links | Reactome: R-HSA-166665Reactome: R-HSA-174577Reactome: R-HSA-375276Reactome: R-HSA-418594Reactome: R-HSA-977606 |
Cellular Localisation | Secreted |
Alternative ELISA Names | Complement C5 ELISA kitC3 And Pzp-Like Alpha-2-Macroglobulin Domain-Containing Protein 4 Cleaved Into - Complement C5 Beta Chain - Complement C5 Alpha Chain - C5a Anaphylatoxin - Complement C5 Alpha' Chain ELISA kitC5 ELISA kitCPAMD4 ELISA kit |
Specificity | This kit recognizes Human C5 in samples. No significant cross-reactivity or interference between Human C5 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 89-100 | 95 |
EDTA plasma (n=8) | 95-108 | 100 |
Cell culture media (n=8) | 93-106 | 100 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 253.77 | 643.02 | 2124.74 | 257.27 | 684.79 | 2226.57 |
Standard deviation | 15.18 | 30.80 | 102.41 | 15.51 | 38.42 | 98.86 |
CV (%) | 5.98 | 4.79 | 4.82 | 6.03 | 5.61 | 4.44 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance