• Human BMP1 (Bone morphogenetic protein 1) CLIA Kit (STJC0000318)

Human BMP1 (Bone morphogenetic protein 1) CLIA Kit (STJC0000318)

SKU:
STJC0000318

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human BMP1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: BMP1
Gene ID: 649
Uniprot ID: BMP1_HUMAN
Specificity: This kit recognizes Human BMP-1 in samples. No significant cross-reactivity or interference between Human BMP-1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Ubiquitous.
Post Translational Modifications Proteolytically activated in the trans-Golgi network by furin-like/paired basic proprotein convertases, cleavage is not required for secretion.
Function Metalloprotease that plays key roles in regulating the formation of the extracellular matrix (ECM) via processing of various precursor proteins into mature functional enzymes or structural proteins. Thereby participates in several developmental and physiological processes such as cartilage and bone formation, muscle growth and homeostasis, wound healing and tissue repair. Roles in ECM formation include cleavage of the C-terminal propeptides from procollagens such as procollagen I, II and III or the proteolytic activation of the enzyme lysyl oxidase LOX, necessary to formation of covalent cross-links in collagen and elastic fibers. Additional substrates include matricellular thrombospondin-1/THBS1 whose cleavage leads to cell adhesion disruption and TGF-beta activation. Isoform BMP1-3: Plays an important role in bone repair by acting as a coactivator of BMP7.
Protein Name Bone Morphogenetic Protein 1
Bmp-1
Mammalian Tolloid Protein
Mtld
Procollagen C-Proteinase
Pcp
Database Links Reactome: R-HSA-1474228
Reactome: R-HSA-1650814
Reactome: R-HSA-2214320
Reactome: R-HSA-2243919
Reactome: R-HSA-8963896 P13497-3
Cellular Localisation Golgi Apparatus
Trans-Golgi Network
Secreted
Extracellular Space
Extracellular Matrix
Co-Localizes With Postn In The Golgi
Isoform Bmp1-3: Secreted
Alternative CLIA Names Bone Morphogenetic Protein 1 CLIA kit
Bmp-1 CLIA kit
Mammalian Tolloid Protein CLIA kit
Mtld CLIA kit
Procollagen C-Proteinase CLIA kit
Pcp CLIA kit
BMP1 CLIA kit
PCOLC CLIA kit
Specificity This kit recognizes Human BMP-1 in samples. No significant cross-reactivity or interference between Human BMP-1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-105 97
EDTA plasma(n=8) 96-112 103
Cell culture media(n=8) 101-116 108

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 98.48 227.71 960.15 103.31 218.77 908.62
Standard deviation 11.69 16.67 78.16 12.76 17.90 69.15
CV (%) 11.87 7.32 8.14 12.35 8.18 7.61
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance