• Human BAK1 (Bcl-2 homologous antagonist/killer) CLIA Kit (STJC0000311)

Human BAK1 (Bcl-2 homologous antagonist/killer) CLIA Kit (STJC0000311)

SKU:
STJC0000311

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.09ng/mL
Detection Limit: 0.16~10ng/mL
Short Description: This human BAK1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: BAK1
Gene ID: 578
Uniprot ID: BAK_HUMAN
Specificity: This kit recognizes Human BAK1 in samples. No significant cross-reactivity or interference between Human BAK1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in a wide variety of tissues, with highest levels in the heart and skeletal muscle.
Function Plays a role in the mitochondrial apoptotic process. Upon arrival of cell death signals, promotes mitochondrial outer membrane (MOM) permeabilization by oligomerizing to form pores within the MOM. This releases apoptogenic factors into the cytosol, including cytochrome c, promoting the activation of caspase 9 which in turn processes and activates the effector caspases.
Protein Name Bcl-2 Homologous Antagonist/Killer
Apoptosis Regulator Bak
Bcl-2-Like Protein 7
Bcl2-L-7
Database Links Reactome: R-HSA-111452
Reactome: R-HSA-111457
Reactome: R-HSA-5620971
Cellular Localisation Mitochondrion Outer Membrane
Single-Pass Membrane Protein
Alternative CLIA Names Bcl-2 Homologous Antagonist/Killer CLIA kit
Apoptosis Regulator Bak CLIA kit
Bcl-2-Like Protein 7 CLIA kit
Bcl2-L-7 CLIA kit
BAK1 CLIA kit
BAK CLIA kit
BCL2L7 CLIA kit
CDN1 CLIA kit
Specificity This kit recognizes Human BAK1 in samples. No significant cross-reactivity or interference between Human BAK1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 101-115 107
EDTA plasma(n=8) 85-96 90
Cell culture media(n=8) 92-108 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.47 0.84 4.13 0.50 0.83 3.95
Standard deviation 0.06 0.08 0.44 0.06 0.08 0.32
CV (%) 12.77 9.52 10.65 12.00 9.64 8.10