Applications: |
ELISA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.19ng/mL |
Detection Limit: |
0.31~20ng/mL |
Short Description: |
This ANXA5 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human cell culture supernatant, serum and plasma (EDTA, citrate, heparin). |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Colormetric |
Gene Symbol: |
ANXA5 |
Gene ID: |
308 |
Uniprot ID: |
ANXA5_HUMAN |
Specificity: |
This kit recognizes Human ANXA5 in samples. No significant cross-reactivity or interference between Human ANXA5 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | This protein is an anticoagulant protein that acts as an indirect inhibitor of the thromboplastin-specific complex, which is involved in the blood coagulation cascade. |
Protein Name | Annexin A5Anchorin CiiAnnexin VAnnexin-5Calphobindin ICpb-IEndonexin IiLipocortin VPlacental Anticoagulant Protein 4Pp4Placental Anticoagulant Protein IPap-IThromboplastin InhibitorVascular Anticoagulant-AlphaVac-Alpha |
Database Links | Reactome: R-HSA-114608 |
Alternative ELISA Names | Annexin A5 ELISA kitAnchorin Cii ELISA kitAnnexin V ELISA kitAnnexin-5 ELISA kitCalphobindin I ELISA kitCpb-I ELISA kitEndonexin Ii ELISA kitLipocortin V ELISA kitPlacental Anticoagulant Protein 4 ELISA kitPp4 ELISA kitPlacental Anticoagulant Protein I ELISA kitPap-I ELISA kitThromboplastin Inhibitor ELISA kitVascular Anticoagulant-Alpha ELISA kitVac-Alpha ELISA kitANXA5 ELISA kitANX5 ELISA kitENX2 ELISA kitPP4 ELISA kit |
Specificity | This kit recognizes Human ANXA5 in samples. No significant cross-reactivity or interference between Human ANXA5 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 89-103 | 95 |
EDTA plasma (n=8) | 92-108 | 99 |
Cell culture media (n=8) | 84-97 | 91 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 1.08 | 2.38 | 6.78 | 1.15 | 2.30 | 7.38 |
Standard deviation | 0.07 | 0.10 | 0.21 | 0.06 | 0.13 | 0.24 |
CV (%) | 6.48 | 4.20 | 3.10 | 5.22 | 5.65 | 3.25 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance