Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human GFAP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
GFAP |
Gene ID: |
2670 |
Uniprot ID: |
GFAP_HUMAN |
Specificity: |
This kit recognizes Human GFAP in samples. No significant cross-reactivity or interference between Human GFAP and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Expressed in cells lacking fibronectin. |
Post Translational Modifications | Phosphorylated by PKN1. |
Function | GFAP, a class-III intermediate filament, is a cell-specific marker that, during the development of the central nervous system, distinguishes astrocytes from other glial cells. |
Protein Name | Glial Fibrillary Acidic ProteinGfap |
Database Links | Reactome: R-HSA-1251985Reactome: R-HSA-9613829 |
Cellular Localisation | CytoplasmAssociated With Intermediate Filaments |
Alternative CLIA Names | Glial Fibrillary Acidic Protein CLIA kitGfap CLIA kitGFAP CLIA kit |
Specificity | This kit recognizes Human GFAP in samples. No significant cross-reactivity or interference between Human GFAP and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 92-106 | 98 |
EDTA plasma(n=8) | 94-106 | 101 |
Cell culture media(n=8) | 88-100 | 93 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 216.21 | 554.75 | 1858.10 | 196.81 | 548.78 | 1766.95 |
Standard deviation | 23.24 | 55.25 | 139.73 | 19.62 | 39.90 | 158.67 |
CV (%) | 10.75 | 9.96 | 7.52 | 9.97 | 7.27 | 8.98 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance