• Human DDC (Aromatic-L-amino-acid decarboxylase) CLIA Kit (STJC0000560)

Human DDC (Aromatic-L-amino-acid decarboxylase) CLIA Kit (STJC0000560)

SKU:
STJC0000560

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human DDC kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DDC
Gene ID: 1644
Uniprot ID: DDC_HUMAN
Specificity: This kit recognizes Human DDC in samples. No significant cross-reactivity or interference between Human DDC and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Isoform 2: High expression in kidney.
Function Catalyzes the decarboxylation of L-3,4-dihydroxyphenylalanine (DOPA) to dopamine and L-5-hydroxytryptophan to serotonin.
Protein Name Aromatic-L-Amino-Acid Decarboxylase
Aadc
Dopa Decarboxylase
Ddc
Database Links Reactome: R-HSA-209905
Reactome: R-HSA-209931
Alternative CLIA Names Aromatic-L-Amino-Acid Decarboxylase CLIA kit
Aadc CLIA kit
Dopa Decarboxylase CLIA kit
Ddc CLIA kit
DDC CLIA kit
AADC CLIA kit
Specificity This kit recognizes Human DDC in samples. No significant cross-reactivity or interference between Human DDC and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-109 99
EDTA plasma(n=8) 101-116 108
Cell culture media(n=8) 99-114 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 100.82 236.58 706.22 97.54 220.62 756.44
Standard deviation 12.89 17.46 54.10 8.55 20.94 47.66
CV (%) 12.79 7.38 7.66 8.77 9.49 6.30
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance