| Function | Matrix metalloproteinase that plays an essential role in local proteolysis of the extracellular matrix and in leukocyte migration. Could play a role in bone osteoclastic resorption. Cleaves KiSS1 at a Gly-|-Leu bond. Cleaves NINJ1 to generate the Secreted ninjurin-1 form. Cleaves type IV and type V collagen into large C-terminal three quarter fragments and shorter N-terminal one quarter fragments. Degrades fibronectin but not laminin or Pz-peptide. | 
  | Protein Name | Matrix Metalloproteinase-9Mmp-992 Kda Gelatinase92 Kda Type Iv CollagenaseGelatinase BGelb | 
  | Database Links | Reactome: R-RNO-1433557Reactome: -RNO-1442490Reactome: -RNO-1474228Reactome: -RNO-1592389Reactome: -RNO-2022090Reactome: -RNO-3928665Reactome: -RNO-6798695Reactome: -RNO-9009391 | 
  | Cellular Localisation | SecretedExtracellular SpaceExtracellular Matrix | 
  | Alternative ELISA Names | Matrix Metalloproteinase-9 ELISA kitMmp-9 ELISA kit92 Kda Gelatinase ELISA kit92 Kda Type Iv Collagenase ELISA kitGelatinase B ELISA kitGelb ELISA kitMmp9 ELISA kit | 
  | Specificity | This kit recognizes Rat MMP-9 in samples. No significant cross-reactivity or interference between Rat MMP-9 and analogues was observed. | 
  | Reproducibility | Both intra-CV and inter-CV are | 
 
Information sourced from Uniprot.org
   | Item | Specifications | Storage | 
  | Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months | 
  | Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months | 
  | Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months | 
  | Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months | 
  | Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months | 
  | Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months | 
  | HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months | 
  | Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months | 
  | Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) | 
  | Stop Solution | 1 vial, 10 mL | 2-8°C | 
  | Plate Sealer | 5 pieces |  | 
  | Manual | 1 copy |  | 
  | Certificate of Analysis | 1 copy |  | 
 
   | Sample Type | Range (%) | Average Recovery (%) | 
  | Serum(n=8) | 98-104 | 101 | 
  | EDTA plasma (n=8) | 95-109 | 103 | 
  | Cell culture media (n=8) | 91-101 | 95 | 
 
   |  | Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision | 
  | Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 | 
  | n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 
  | Mean (ng/mL) | 23.64 | 61.14 | 223.70 | 24.02 | 56.48 | 214.26 | 
  | Standard deviation | 1.41 | 2.78 | 9.91 | 1.21 | 2.80 | 11.48 | 
  | CV (%) | 5.96 | 4.55 | 4.43 | 5.04 | 4.96 | 5.36 |