• Human FE (Ferritin) CLIA Kit (STJC0000133)

Human FE (Ferritin) CLIA Kit (STJC0000133)

SKU:
STJC0000133

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human FE kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: FTH1
FTL
Gene ID: 2495
2512
Uniprot ID: FRIH_HUMAN
FRIL_HUMAN
Specificity: This kit recognizes Human FE in samples. No significant cross-reactivity or interference between Human FE and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity
Alternative CLIA Names Ferritin Heavy Chain CLIA kit
Ferritin H Subunit CLIA kit
Cell Proliferation-Inducing Gene 15 Protein Cleaved Into - Ferritin Heavy Chain - N-Terminally Processed CLIA kit
FTH1 CLIA kit
FTH CLIA kit
FTHL6 CLIA kit
OK CLIA kit
SW-cl.84 CLIA kit
PIG15 CLIA kit
Ferritin Light Chain CLIA kit
Ferritin L Subunit CLIA kit
FTL CLIA kit
Specificity This kit recognizes Human FE in samples. No significant cross-reactivity or interference between Human FE and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 95-109 102
EDTA plasma(n=8) 99-112 106
Cell culture media(n=8) 99-115 106

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 92.68 179.57 890.55 84.34 175.84 910.59
Standard deviation 8.58 18.87 90.75 8.11 17.06 66.75
CV (%) 9.26 10.51 10.19 9.62 9.70 7.33
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance