• Human AGRP (Agouti-related protein) CLIA Kit (STJC0000005)

Human AGRP (Agouti-related protein) CLIA Kit (STJC0000005)

SKU:
STJC0000005

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This human AGRP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: AGRP
Gene ID: 181
Uniprot ID: AGRP_HUMAN
Specificity: This kit recognizes Human AgRP in samples. No significant cross-reactivity or interference between Human AgRP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed primarily in the adrenal gland, subthalamic nucleus, and hypothalamus, with a lower level of expression occurring in testis, lung, and kidney.
Function Plays a role in weight homeostasis. Involved in the control of feeding behavior through the central melanocortin system. Acts as alpha melanocyte-stimulating hormone antagonist by inhibiting cAMP production mediated by stimulation of melanocortin receptors within the hypothalamus and adrenal gland. Has very low activity with MC5R. Is an inverse agonist for MC3R and MC4R being able to suppress their constitutive activity. It promotes MC3R and MC4R endocytosis in an arrestin-dependent manner.
Protein Name Agouti-Related Protein
Database Links Reactome: R-HSA-9615017
Cellular Localisation Secreted
Golgi Apparatus Lumen
Alternative CLIA Names Agouti-Related Protein CLIA kit
AGRP CLIA kit
AGRT CLIA kit
ART CLIA kit
Specificity This kit recognizes Human AgRP in samples. No significant cross-reactivity or interference between Human AgRP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-96 90
EDTA plasma(n=8) 95-113 103
Cell culture media(n=8) 91-105 99

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 25.81 80.27 188.20 27.50 74.73 172.76
Standard deviation 3.33 8.70 17.52 3.55 6.72 14.08
CV (%) 12.90 10.84 9.31 12.91 8.99 8.15
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance