• Human ACTN3 (Alpha-actinin-3) CLIA Kit (STJC0000168)

Human ACTN3 (Alpha-actinin-3) CLIA Kit (STJC0000168)

SKU:
STJC0000168

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 46.88pg/mL
Detection Limit: 78.13~5000pg/mL
Short Description: This human ACTN3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: ACTN3
Gene ID: 89
Uniprot ID: ACTN3_HUMAN
Specificity: This kit recognizes Human ACTN3 in samples. No significant cross-reactivity or interference between Human ACTN3 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed only in a subset of type 2 skeletal muscle fibers.
Function F-actin cross-linking protein which is thought to anchor actin to a variety of intracellular structures. This is a bundling protein.
Protein Name Alpha-Actinin-3
Alpha-Actinin Skeletal Muscle Isoform 3
F-Actin Cross-Linking Protein
Database Links Reactome: R-HSA-373753
Reactome: R-HSA-390522
Alternative CLIA Names Alpha-Actinin-3 CLIA kit
Alpha-Actinin Skeletal Muscle Isoform 3 CLIA kit
F-Actin Cross-Linking Protein CLIA kit
ACTN3 CLIA kit
Specificity This kit recognizes Human ACTN3 in samples. No significant cross-reactivity or interference between Human ACTN3 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 96-108 103
EDTA plasma(n=8) 97-109 103
Cell culture media(n=8) 90-103 97

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 253.98 559.86 2190.94 267.68 574.35 2080.57
Standard deviation 22.05 58.56 153.80 27.25 43.82 214.92
CV (%) 8.68 10.46 7.02 10.18 7.63 10.33
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance