• Human ACP5 (Tartrate-resistant acid phosphatase type 5) CLIA Kit (STJC0000694)

Human ACP5 (Tartrate-resistant acid phosphatase type 5) CLIA Kit (STJC0000694)

SKU:
STJC0000694

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.09ng/mL
Detection Limit: 0.16~10ng/mL
Short Description: This human ACP5 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: ACP5
Gene ID: 54
Uniprot ID: PPA5_HUMAN
Specificity: This kit recognizes Human ACP5 in samples. No significant cross-reactivity or interference between Human ACP5 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Involved in osteopontin/bone sialoprotein dephosphorylation. Its expression seems to increase in certain pathological states such as Gaucher and Hodgkin diseases, the hairy cell, the B-cell, and the T-cell leukemias.
Protein Name Tartrate-Resistant Acid Phosphatase Type 5
Tr-Ap
Tartrate-Resistant Acid Atpase
Tratpase
Type 5 Acid Phosphatase
Database Links Reactome: R-HSA-196843
Cellular Localisation Lysosome
Alternative CLIA Names Tartrate-Resistant Acid Phosphatase Type 5 CLIA kit
Tr-Ap CLIA kit
Tartrate-Resistant Acid Atpase CLIA kit
Tratpase CLIA kit
Type 5 Acid Phosphatase CLIA kit
ACP5 CLIA kit
Specificity This kit recognizes Human ACP5 in samples. No significant cross-reactivity or interference between Human ACP5 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-106 98
EDTA plasma(n=8) 90-105 96
Cell culture media(n=8) 89-102 97

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.55 0.91 4.72 0.56 0.97 4.61
Standard deviation 0.07 0.10 0.51 0.06 0.11 0.39
CV (%) 12.73 10.99 10.81 10.71 11.34 8.46
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance